Pocket pulse oximeter monitor CMS50+
- fingertip pulse oximeter
- oximeter monitor
- Pocket pulse oximeter monitor
- Product description: *Integrated with SpO2 probe and processing display module *Small in volume ,light in weight and convenient in carrying *Operation of the product is simple ,low power consumption *Operation menu for
Product introduction
Major Features
* Integrated with SpO2 probe and processing display module
* Small in volume ,light in weight and convenient in carrying
* Operation of the product is simple ,low power consumption
* Operation menu for the function setting
* SpO2 value display
* Pulse rate value display, bar graph display
* Pulse waveform display
* The display mode can be changed
* A pulse rate sound indication
* With measured data overruns limits and low-voltage alarm function, the upper/down alarm range is adjustable
* Low-voltage indication: low-voltage indicator appears before working abnormally which is due to low-voltage, and with alarm function
* With SpO2 value and pulse rate value of storage, the storage data can be uploaded to computers
* Real-time data can be transmitted to computers
* Automatically power off function: when the device is under the state of measuring interface . it will automatically power off within 5 seconds if the finger falls out of probe
* RF Wireless communication function(Option)
* Connected with an external oximeter probe(Option)
Main performance
Display Mode: 0.96" Dual color OLED display
Screen Resolution: 128*64
SpO2 Measuring Range: 0%~100%, (the resolution is 1%).
Accuracy: 70%~100%: +/-2% ,Below 70% unspecified.
PR Measuring Range: 30bpm~250bpm, (the resolution is 1bpm)
Accuracy: +/-2bpm or +/-2% (select larger)
Measurement Performance in Weak Filling Condition:
SpO2 and pulse rate can be shown correctly when pulse-filling ratio is 0.4%. SpO2 error is +/-4%, pulse rate error is +/-2 bpm or +/-2% (select larger).
Resistance to Surrounding Light: The deviation between the value measured in the condition of man-made light or indoor natural light and that of darkroom is less than +/-1%.
Power Consumption: less than 80mA
Voltage: DC 3.0V
Power Supply: 1.5V (AAA size) alkaline batteries *2
Battery Working Hour: The minimum continually work time is 24 hours , theoretical number is 32 hours.
Safety Type: Interior Battery, BF Type
Accessories
Sell in standard:
* A hanging rope
* A user manual
* A data line
* A disk (PC software)
Sell in addition:
* RF wireless module
* Oximeter probe(Refer to probe application instruction for details and notice renewal)
Physical Identity
Dimension: 58.5(L) *31(W) *32 (H) mm
Weight: About 52g (with the batteries)
Qualification
Passed CE