			Pocket pulse oximeter monitor CMS50+
- fingertip pulse oximeter
 - oximeter monitor
 - Pocket pulse oximeter monitor
 - Product description: *Integrated with SpO2 probe and processing display module *Small in volume ,light in weight and convenient in carrying *Operation of the product is simple ,low power consumption *Operation menu for
 
Product introduction
Major Features
	
* Integrated with SpO2 probe and processing display module
 * Small in volume ,light in weight and convenient in carrying
 * Operation of the product is simple ,low power consumption
 * Operation menu for the function setting
 * SpO2 value display
 * Pulse rate value display, bar graph display
 * Pulse waveform display
 * The display mode can be changed
 * A pulse rate sound indication
 * With measured data overruns limits and low-voltage alarm function, the upper/down alarm range is adjustable
 * Low-voltage indication: low-voltage indicator appears before working abnormally which is due to low-voltage, and with alarm function
 * With SpO2 value and pulse rate value of storage, the storage data can be uploaded to computers
 * Real-time data can be transmitted to computers
 * Automatically power off function: when the device is under the state of measuring interface . it will automatically power off within 5 seconds if the finger falls out of probe
 * RF Wireless communication function(Option)
 * Connected with an external oximeter probe(Option)
	Main performance
Display Mode: 0.96" Dual color OLED display
 Screen Resolution: 128*64
 SpO2 Measuring Range: 0%~100%, (the resolution is 1%).
 Accuracy: 70%~100%: +/-2% ,Below 70% unspecified.
 PR Measuring Range: 30bpm~250bpm, (the resolution is 1bpm)
 Accuracy: +/-2bpm or +/-2% (select larger)
 Measurement Performance in Weak Filling Condition:
 SpO2 and pulse rate can be shown correctly when pulse-filling ratio is 0.4%. SpO2 error is +/-4%, pulse rate error is +/-2 bpm or +/-2% (select larger).
 Resistance to Surrounding Light: The deviation between the value measured in the condition of man-made light or indoor natural light and that of darkroom is less than +/-1%.
 Power Consumption: less than 80mA
 Voltage: DC 3.0V
 Power Supply: 1.5V (AAA size) alkaline batteries *2 
 Battery Working Hour: The minimum continually work time is 24 hours , theoretical number is 32 hours.
 Safety Type: Interior Battery, BF Type
	Accessories
Sell in standard:
 * A hanging rope
 * A user manual 
 * A data line
 * A disk (PC software)
 Sell in addition:
 * RF wireless module
 * Oximeter probe(Refer to probe application instruction for details and notice renewal)
	Physical Identity
 Dimension: 58.5(L) *31(W) *32 (H) mm
 Weight: About 52g (with the batteries)
	
	Qualification
Passed CE
	